KITS THAT ARE APPLICABLE TO ALL G-LINE TRANSMITTERS.

 

MI-563392-1 DRIVER POWER SUPPLY SOFT START KIT.  DATE ISSUED - 4/16/80

PURPOSE - ENSURES THAT CIRCUIT BREAKER DOES NOT TRIP WHEN REPEATED SHORT TERM POWER INTERRUPTIONS OCCUR.  THIS KIT INSTALLED A SOFT START A500 PC BOARD IN THE POWER SUPPLY.

 

MI-563392-2 NOT ISSUED

 

MI-563392-3 HYBRID AMPLIFIER HEAT SINK KIT.  DATE ISSUED - 10/15/80

PURPOSE - THIS KIT WAS DESIGNED TO PREVENT THE HYBRID AMPLIFIERS AT THE OUTPUTS OF BOTH THE VISUAL AND AURAL OUTPUT MIXER BOARDS FROM OVERHEATING.

 

MI-563392-4 AURAL AIR PRESSURE METER.  DATE ISSUED - 10/8/80

PURPOSE - THIS KIT REPLACED THE AIR PRESSURE METER FROM 0 -20" TO 0 - 10" SO THAT A MORE ACCURATE READING COULD BE TAKEN.

 

MI-563392-5 NOT ISSUED

 

MI-563392-6 FILAMENT SUPPLY MODIFICATION FOR 220V/50HZ..  DATE ISSUED - 11/18/80

PURPOSE - TO MODIFY THE TRANSFORMERS IN THE COMBINED VISUAL AND AURAL FILAMENT POWER SUPPLY TO ALLOW OPERATION WITH 220 VOLT, 50 HZ AC MAINS INPUT.

 

MI-563392-7 VSWR / POWER METERING FILTER KIT.  DATE ISSUED - 1/15/81

PURPOSE - THIS KIT IS USED TO PREVENT INTERACTION BETWEEN THE VISUAL AND AURAL POWER METERS AND IS TO BE USED IN CONJUNCTION WITH EITHER MI-563235-5 OR MI-563235-5A VSWR INDICATOR MODULE.

 

MI-563392-8 PARALLEL SYSTEM LOSS OF VIDEO KIT.  DATE ISSUED - 3/6/81

PURPOSE - TO PROVIDE THE MEANS OF REDUCING THE OUTPUT POWER OF BOTH TRANSMITTERS IN A PARALLEL SYSTEM TO A SAFE LEVEL WHEN A LOSS OF VIDEO IS DETECTED IN THE ACTIVE EXCITER.

 

MI-563392-9 VIDEO/SYNC GAIN CONTROL FOR PARALLEL SYSTEMS.  DATE ISSUED - 4/15/81

PURPOSE - TO PROVIDE THE CAPABILITY TO REMOTE CONTROL THE "ON AIR" VIDEO AND SYNC GAIN IN A PARALLEL SYSTEM.

 

MI-563392-10 SOLID STATE AMPLIFIER CONNECTOR REPLACEMENT KIT.  DATE ISSUED - 5/1/81

PURPOSE - TO REPLACE THE AMP HIGH CURRENT CONTACTS IN THE BLACK AMP CONNECTORS WITH THE NEWER MORE RELIABLE TYPE.

 

 

MI-563392-11 TORQUE SCREWDRIVER, TRANSISTOR MOUNTING.  DATE ISSUED - 5/3/81

PURPOSE - PROVIDE A TORQUE SCREWDRIVER TOGETHER WITH INSTRUCTIONS ON REPLACING AMPLIFIER BOARDS WITHIN THE PRE‑TUNED UNITS SUCH AS THE 400 WATT AMP, THE PREDRIVER AND THE AURAL AMPLIFIERS.

 

 

MI-563392-12 PARALLEL SYSTEMS TEST KIT.  DATE ISSUED - 8/7/81

PURPOSE - TO PROVIDE THE MATERIAL AND INFORMATION NECESSARY TO PERMIT THE TESTING OF ONE SIDE OF A PARALLEL SYSTEM WHILE THE OTHER SIDE IS ON THE AIR.

 

MI-563392-13 LOGIC & POWER LINE TRANSIENT PROTECTION IN SCREEN PS's.  DATE ISSUED - 8/25/81

PURPOSE - TO PROVIDE BOTH THE AC INPUT AND THE DC LOGIC INPUT WITH TRANSIENT PROTECTION.  INSTALLATION OF THIS KIT CONVERTS AN MI-563209A (VISUAL) TO AN MI-563209B AND AN MI-563210A (AURAL) TO AN MI-563210B.

 

MI-563392-14 LOGIC PROTECTION & VOLTAGE CHANGE KIT IN AURAL BIAS SUPPLY.  ISSUED - 8/25/81

PURPOSE - SAME AS ABOVE KIT BUT FOR THE AURAL BIAS SUPPLY.  INSTALLATION OF THIS KIT MADE AN MI-563211A INTO AN MI-563211B.

 

MI-563392-15 LOGIC PROTECTION & SINK/SOURCE IMPROVEMENT KIT.  DATE ISSUED - 10/20/81

PURPOSE - SIMILAR TO ABOVE KIT BUT FOR VISUAL BIAS SUPPLY USED IN 17H AND 16L TRANSMITTERS.  INSTALLATION OF THIS KIT MADE AN MI-563207A INTO AN MI-563207B.

 

MI-563392-16 LOGIC PROTECTION & SINK/SOURCE IMPROVEMENT KIT.  DATE ISSUED - 10/20/81

PURPOSE - SAME AS ABOVE KIT BUT FOR VISUAL BIAS SUPPLIES USED IN THE 30H AND 30L TRANSMITTERS.

 

MI-563392-17 CONTROL LOGIC POWER SUPPLY PROTECTION KIT.  DATE ISSUED - 7/2/81

PURPOSE - TO REDUCE VOLTAGE SPIKES TO SAFE LEVEL BY INSTALLING A METAL OXIDE VARISTOR ACROSS THE PRIMARY WINDING OF THE CONTROL LOGIC POWER SUPPLY TRANSFORMER T2 IN THE POWER SUPPLY CONTROL CABINET.

 

MI-563392-18 AURAL CARRIER SHUTDOWN KIT. DATE ISSUED - 7/20/81

PURPOSE - TO PROVIDE A MEANS OF TURNING OFF THE AURAL CARRIER IF THE VISUAL CARRIER SYNTHESIZER, OR THE VISUAL IF SYNTHESIZER, OR THE AURAL IF SYNTHESIZER BECOME UNLOCKED.  THIS KIT IS NOT REQUIRED IN PARALLEL SYSTEMS.

 

MI-563392-19 VIDEO TRAY HOLD DOWN KIT. DATE ISSUED - 7/21/81

PURPOSE - THIS KIT IS DESIGNED TO PREVENT THE PC BOARDS IN THE VIDEO TRAY FROM BECOMING LOOSE BY MECHANICALLY SECURING THE BOARDS IN PLACE.

 

MI-563392-20 SOLID STATE AMPLIFIER RF CONNECTOR MAINTENANCE KIT.  DATE ISSUED - 6/29/81

PURPOSE - TO ENSURE THAT THE RF INPUT AND OUTPUT CONNECTORS ON BOTH HIGH AND LOW BAND 400 WATT AMPLIFIERS ARE SECURED PROPERLY AND THAT THE SOLDERED CONNECTIONS ARE GOOD.  ALSO, TO CHECK IN THE 400 WATT LOW BAND AMPLIFIERS THAT THE BALUN COIL ASSEMBLIES HAVE NOT BROKEN LOOSE FROM THE GROUND PLANE OF THE PC BOARD.

 

 

 

 

MI-563392-21  PLUS AND MINUS 15 VOLT POWER SUPPLY KIT.  DATE ISSUED - 7/6/81

PURPOSE - TO ASSURE STABLE OPERATION AT ALL TEMPERATURES, CURRENT AND CURRENT LIMIT CONDITIONS.  THIS IS ACCOMPLISHED BY REMOVING CAPACITOR C10 (10MFD, 16VDC) FROM THE +15V SUPPLY.  IN THE -15V SUPPLY IT INVOLVES CUTTING THE CIRCUIT TRACE AT A PARTICULAR POINT AND ADDING A 1 OHM 11 WATT RESISTOR.

 

MI-563392-22 SCREEN SUPPLY CUTOFF KIT.  DATE ISSUED - 7/24/81

PURPOSE - TO PREVENT SCREEN SUPPLY OUTPUT VOLTAGE LEAKAGE AND TO ELIMINATE FALSE TRIGGERING CAUSED BY NOISE INDUCED INTO THE SUPPLY'S CONTROL LINE.  THIS WAS INITIALLY A KIT THAT WAS INSTALLED ONLY IN TRANSMITTERS OPERATING WITH 480V AC INPUT LINE VOLTAGE.  WHEN THE C VERSION OF THE SCREEN SUPPLY CAME OUT IT WAS NOT REQUIRED IN ANY TRANSMITTERS SINCE THE ON/OFF CONTROL WAS BY A MECHANICAL RELAY.  IT WAS NOT USED OR NEEDED IN THE 35H OR 50H.  SINCE IT WAS NOT REQUIRED IN ALL TRANSMITTERS, IT WAS NOT ISSUED AS A KIT.

 

MI-563392-23 LUMINANCE LINEARITY CORRECTOR KIT.  DATE ISSUED - 8/11/81

PURPOSE - TO CORRECT FOR LOW FREQUENCY LUMINANCE LINEARITY ERRORS INCURRED THROUGH THE SYSTEM.  THIS WAS INITIALLY DESIGNED FOR THE 50H AND 35H TRANSMITTERS SINCE THOSE SYSTEMS PRODUCED MORE OF AN ERROR IN THIS AREA.  IT WAS DECIDED NOT TO PUT THIS OUT AS A KIT, ONLY AS AN UPGRADE ON ALL FUTURE TRANSMITTERS.  IF YOUR TRANSMITTER WAS PURCHASE EARLY IN 1982 IT WOULD HAVE THE CORRECTOR IN PLACE IN THE VIDEO TRAY. THE VIDEO TRAY WOULD BE AN MI-563111A, NOT AN MI-563111.

 

MI-563392-24  NOT ISSUED

 

MI-563392-25 PLATE SUPPLY COOLING MODIFICATION.  DATE ISSUED - 10/15/81

PURPOSE - TO PROVIDE GREATER AIR FLOW ACROSS THE PLATE TRANSFORMER ON THE HV POWER SUPPLY.  I BELIEVE THIS KIT WAS ONLY PUT ON 30 KW UNITS AND ONLY IF THEY WERE OPERATING AT FULL OR NEAR FULL POWER.  IT DID NOT GET INSTALLED AS A KIT ON THE 17 AND 16 KW TRANSMITTERS AND IS NOT APPLICABLE TO THE 35 AND 50 KW UNITS.

 

MI-563392-26 CONTROL INPUT PULL UP RESISTOR.  DATE ISSUED - 3/17/82

PURPOSE - TO ADD A PULL UP RESISTOR BETWEEN U29 PIN 11 AND THE +5 VOLT SUPPLY ON THE CONTROL INPUT MODULE MI-563261-1.

 

MI-563392-27 VSWR RESET KIT.  DATE ISSUED - 6/30/82

PURPOSE - WHEN INSTALLED, THE VSWR RESET KIT PROVIDED THE CIRCUITRY NECESSARY FOR RESETTING THE DRIVER CONTROL CIRCUIT AUTOMATICALLY UNDER THE CONTROL OF THE COUNTER CIRCUITRY IN THE POWER SUPPLY/CONTROL CABINET.  THE VSWR RESET KIT IS INTENDED FOR USE BY ITSELF OR AS A PART OF THE CONTACTOR CONTROL KIT MI-563392-28.

 

MI-563392-28 CONTACTOR CONTROL KIT.  DATE ISSUED - 7/1/82

PURPOSE - THIS KIT CONNECTS A THREE-PHASE AC CONTACTOR IN SERIES WITH THE AC INPUT TO THE DRIVER POWER SUPPLY.  WHEN AN OVERVOLTAGE FAULT OCCURS IN THE DRIVER POWER SUPPLY, A VOLTAGE IS DEVELOPED ACROSS THE RESISTOR IN SERIES WITH THE CROWBAR SCR AT THE OUTPUT OF THE SUPPLY.  RELAY K3 ON THE VSWR RESET MODULE ENERGIZES WHICH DISCONNECTS THE AC INPUT TO THE AC CONTACTOR, THUS ENERGIZING THE CONTACTOR FOR A PRESET TIME.

 

 

MI-563392-29 SYNTHESIZER STABILIZATION KIT.  DATE ISSUED - 6/23/82

PURPOSE - TO IMPROVE THE PHASE NOISE CHARACTERISTICS OF EITHER THE LOW BAND VISUAL SYNTHESIZER MI-563121 OR THE HIGH BAND SYNTHESIZER MI-563123.  ALSO TO IMPROVE THE FREQUENCY VS TEMPERATURE CHARACTERISTICS OF THE AURAL EXCITER MI-563122A/B.

 

MI-563392-30 THERMAL PROTECTION KIT.  DATE ISSUED - 9/28/82

PURPOSE - PROVIDES INSTRUCTIONS AND MATERIAL TO CONNECT THE THERMAL SENSORS WITHIN THE PLATE TRANSFORMER IN PARALLEL WITH S3 "TEMP HI" SENSOR INSIDE THE POWER SUPPLY/CONTROL CABINET.  ALSO PROVIDES INSTRUCTIONS AND MATERIAL TO CONNECT THE COOLING FAN MOUNTED ON TOP OF THE HV POWER SUPPLY INTO THE CONTROL CABINET WIRING.

 

MI-563392-31 RESISTOR & REGULATOR KIT, SCREEN SUPPLIES.  DATE ISSUED - 7/30/82

PURPOSE - MODIFIES HEATSINK BOARD #4 IN BOTH THE VISUAL AND AURAL SUPPLIES BY MOVING A JUMPER AND CUTTING THE TRACK.  INSTALLATION OF THIS KIT CONVERTS AN MI-563209 B OR C INTO AN MI-563209 B1 OR C1 AND AN MI-563210 B OR C INTO AN MI-563210 B1 OR C1.

 

MI-563392-32 G-LINE PARALLEL RACK BREAKER PANEL KIT.  DATE ISSUED - 12/8/83

PURPOSE - TO REPLACE CIRCUIT BREAKER CB1 FOR 480V LINE OPERATION ON THE TRANSFORMER TRAY (FRONT) PANEL.